arrow-left-2arrow-left-3arrow-left-4arrow-leftchronodiggdown-arrow--lineardown-arrowearthenvelopefacebookfacebook_ (2)facebook_forward-arrowforwardgooglehomeico-downloadico-linkindustries--1industries--10industries--10_oldindustries--2industries--3industries--4industries--5industries--6industries--6_oldindustries--7industries--8industries--9linkedinmailmarkernewspaperpadlockpage-arrow-leftpage-arrow-rightpage-listpencilpinterestplay-buttonprintersearchsocial-diggsocial-facebooksocial-googlesocial-instagramsocial-linkedinsocial-pinterestsocial-twittersocial-youtubestartelephonetwittertwitter_user

Non-contact measurement with ChromaPoint controller

CCS SERIES

CCS controllers allow high precision measurements without contact and without risk of damaging the parts.

Among the various advantages of CCS controllers is the measurement of distance and thickness at very high resolution on all types of surfaces and materials, including reflective surfaces.

Thickness measurement on glass or transparent films is achieved with a single CCS controller, a single high-precision sensor head, a maximum measurement frequency of 2 to 10 kHz and sub-micron accuracy.

CCS controllers are compatible with all STIL sensor heads (CL-MG, OP, ENDO, EVEREST...) with a performance adapted to each measurement range.

Non Contact Chromapoint Controller
DESCRIPTION

CCS series controllers are composed of different models (one channel or two multiplexed channels) which, in combination with the large variety of STIL point sensor heads, allow to offer excellent metrological performances (down to the nanometer).

Built according to the highest quality standards since 2005, CCS series are robust and reliable products, suitable for industrial and laboratory use.

This reference is available up to 2000Hz with CCS PRIMA and up to 10000 Hz with CCS OPTIMA+ in order to provide solutions in multiple application contexts and on any type of surface reflectivity: transparent or opaque, bright or diffuse.

BENEFITS
  • Chromatic confocal technology can measure any material capable of reflecting white light (e.g. metal, glass, plastic, paint films, liquids)
  • Non-contact measurement is suitable in all cases where it is necessary to measure without touching the target
  • High measurement accuracy
  • Interchangeable STIL optical heads: CL-MG / OP / ENDO / EVEREST series
  • CCS controller can store up to 20 cards to allow the most appropriate probe to be used
  • Availability of SDK and protocol commands for easy integration into any system
  • Synchronized measurement with encoder for dynamic acquisitions
  • Several interfaces for communication: analog, USB, RS232/422
TECH SPECS

Model

CCS-Prima

CCS-Prima 2

CCS-Prima 4

CCS-Prima+

CCS-Optima+

Order Code

O8ST10M1001

O8ST11M1001

O8ST12M1001

O8ST13M1009

O8ST09M2001

Technology

Chromatic Confocal

Source

White LED

Number of channel

1

2 (multiplexed)

4 (multiplexed)

1

1

Measuring Frequency

From 100 Hz to 2000 Hz

From 500 Hz to 10000 Hz

Calibration table memory

Up to 20 calibration tables

Distance Measurement

First/Strongest peak

Thickness Measurement

2 Peaks

Advanced features

AutoLed/AutoDark/DoubleFrequency/HoldLastValue…

Digital Output

RS232, RS422 and USB

Synchronization

Trigger in&out

Other Input/Output

2 Analog Output, Encoder Input (up to 3)

Fiber connection

E2000/APC

Temperature in use

5°C - 50°C

Storage temperature

-30°C - 70°C

Relative humidity

5% - 80% HR without condensation

Protection type

IP 20

Compliance

EN 61326-1

-

-

EN 61326-1

EN 61326-1

Power Supply

24V DC

Maximum/Usual Consumption

25W/8W

25W/9W

Dimensions

162mm x 138,1mm x 111,5mm

Weight

1,2kg

1,2kg

1,6kg

1,2kg

1,2kg

APPLICATIONS

​The chromatic confocal technology of CCS series is suitable for a variety of applications in many fields:

  • Automotive glass
  • Glass containers and packaging industry
  • Electrical vehicle industry (batteries)
  • Applications for measuring roll-to-roll, transparent and non-transparent films (e.g. EV battery covers, flexible electronics)
  • Electronics Industry (PCB)
  • Semiconductor industry (silicon wafer)
  • CCC industry
  • Medical
  • Micromechanics
  • Aviation/Aerospace
  • Watchmaking
  • Robotics
VERSIONS

CCS controllers are available in two versions: CCS PRIMA series and CCS OPTIMA+.

CCS PRIMA is available with one, two or four multiplexed channels.

For specific applications such as glass thickness measurement, CCS PRIMA+ offers a higher light output level.

For OEM integration, CCS PRIMA is available in CCS BOXLESS version.

Download

BROCHURES AND MANUALS

Data Sheet
English CCS SERIES: (932.79kB)
CCS PRIMA+: (816.96kB)
CCS PRIMA 2: (839.08kB)
CCS PRIMA: (814.94kB)
CCS OPTIMA+: (798.92kB)
CCS BOXLESS: (819.17kB)

Related applications

Close
Close

Request information

Insert your first name
Insert your last name
Insert the company name
Insert your email

To help the message delivery directly to the division in charge, please select the application field in the list below:

Insert your message

Before sending the form please read carefully the INFORMATION NOTICE on personal data processing provided in accordance with the Regulation EU 2016/679.

Please accept the privacy policy
Top Contact us