E32R
INTERFACE UNIT FOR HARD-WIRED CONNECTION OF MIDA PROBES
The E32R interface converts the signal generated by the touch probe into
a form which can be used by the machine tool CNC.
On the front panel of the unit are located the terminal boxes for the
I/O connections and some LED's to indicate the following:
- Green LED: lit to indicate "power ON"
- Green LED: indicates the status of the touch probe:
- lit when the probe stylus is deflected
- unlit when the probe is seated.
| 32R interface technical features | |
| Power supply | nominal 24 VDC (15-30 V) |
| Power input | 50 mA max. |
| Output type | Solid State Relay (SSR) 50 V; 40 mA |
| Protection degree | IP 20 (EN 60529 std.) |

Enlarge the image